Solenoid Valves for Air VRA, VLA, VTA
- Easily adjust high- and low-fire settings
- Bypass bore available (optional)
- Suitable for pulse-fire applications (high duty cycle)
- A range of pipe sizes and opening/closing behaviors

Learn More:
Description Documentation Ordering Information Accessories
Ordering Information
| Model and Description | Stock | Price | Cart |
| VRA2-2N.T1 Fast Open/Fast Close; ¾" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VRA3-2N.T1 Fast Open/Fast Close; 1" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VRA35-2N.T1 Fast Open/Fast Close; 1¼" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VRA4-2N.T1 Fast Open/Fast Close; 1½" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VRA6-2N.T1 Fast Open/Fast Close; 2" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VRA6F-2N.T1 Fast Open/Fast Close; 2" pipe size; ANSI Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VRA7T-2N.T1 Fast Open/Fast Close; 2½" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VRA78-2N.T1 Fast Open/Fast Close; 2½", 3" pipe size; ANSI Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VLA2-2N.T1 Slow Open/Fast Close; ¾" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VLA3-2N.T1 Slow Open/Fast Close; 1" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VLA35-2N.T1 Slow Open/Fast Close; 1¼" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VLA4-2N.T1 Slow Open/Fast Close; 1½" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VLA6-2N.T1 Slow Open/Fast Close; 2" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VLA6F-2N.T1 Slow Open/Fast Close; 2" pipe size; ANSI Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VLA7T-2N.T1 Slow Open/Fast Close; 2½" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VLA78-2N.T1 Slow Open/Fast Close; 2½", 3" pipe size; ANSI Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VTA35-2N.T1 Slow Open/Slow Close; 1¼" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VTA4-2N.T1 Slow Open/Slow Close; 1½" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VTA6-2N.T1 Slow Open/Slow Close; 2" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VTA6F-2N.T1 Slow Open/Slow Close; 2" pipe size; ANSI Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VTA7T-2N.T1 Slow Open/Slow Close; 2½" pipe size; NPT Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
|||
| VTA78-2N.T1 Slow Open/Slow Close; 2½", 3" pipe size; ANSI Connection; Max. Pressure: 3 PSI; 120V AC; Wiring via DIN Plug & Socket |
Description
Elektrogas solenoid valves for air VRA, VLA, and VTA are normally closed (open when energized) and are suitable for use with cold combustion air. They are ideal for high/low control of combustion air in industrial gas burners.
Documentation
| Industrial Solenoid Valve VRA, VLA, VTA Technical Information | |
| Industrial Solenoid Valve VRA, VLA, VTA Installation Instructions | |
| PG9-1/2NPT Adapter Installation Instructions |
Accessories
| Model and Description | Stock | Price | Cart |
| PG9-1/2NPT Adapter 1/2" Adapter for ISO plug to Elektrogas Valve. Learn more at FAQ: Adapting ISO Plugs to Elektrogas Valves. |