Butterfly Valve for Gas and Air BVG

  • For gas, air, hot air and flue gas
  • Low leakage rate and pressure loss
  • High control accuracy
  • Reduced nominal diameters
  • Can be mounted directly onto the actuators IC 20 or IC 40
  • Suitable for intermittent operation
  • Low-maintenance operation
Butterfly Valve BVG

Learn More:
Description   Documentation   Ordering Information   Accessories

Ordering Information

   

Alternate Product

Model and
Description
Model Bore Diameter Max inlet pressure Connection Fitting Lead Time   Model Lead Time Order
BVG 40W05
Bore diameter: 1½″; Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (1½″)
BVG 40W05 1½″ 500 mbar (7.25 psig) between two ANSI flanges (1½″) Not Available   VF4
BVG 50W05
Bore diameter: 2″; Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2″)
BVG 50W05 2″ 500 mbar (7.25 psig) between two ANSI flanges (2″) Not Available   VF6
BVG 65W05
Bore diameter: 2½″; Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2½″)
BVG 65W05 2½″ 500 mbar (7.25 psig) between two ANSI flanges (2½″) Not Available   VF7
BVG 80W05
Bore diameter: 3″; Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (3″)
BVG 80W05 3″ 500 mbar (7.25 psig) between two ANSI flanges (3″) Not Available   VF8
BVG 100W05
Bore diameter: 4″; Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (4″)
BVG 100W05 4″ 500 mbar (7.25 psig) between two ANSI flanges (4″) Not Available   VF9
BVG 40/32W05
Bore diameter: 1¼″ (reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (1½″)
BVG 40/32W05 1¼″ (reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (1½″) Not Available   VF4x1
BVG 50/40W05
Bore diameter: 1½″ (reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2″)
BVG 50/40W05 1½″ (reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (2″) Not Available   VF6x1
BVG 65/50W05
Bore diameter: 2″ (reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2½″)
BVG 65/50W05 2″ (reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (2½″) Not Available   VF7x1
BVG 80/65W05
Bore diameter: 2½″ (reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (3″)
BVG 80/65W05 2½″ (reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (3″) Not Available   VF8x1
BVG 100/80W05
Bore diameter: 3″ (reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (4″)
BVG 100/80W05 3″ (reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (4″) Not Available   VF9x1
BVG 40/25W05
Bore diameter: 1″ (2 × reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (1½″)
BVG 40/25W05 1″ (2 × reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (1½″) Not Available   VF4x2
BVG 50/32W05
Bore diameter: 1¼″ (2 × reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2″)
BVG 50/32W05 1¼″ (2 × reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (2″) Not Available   VF6x2
BVG 65/40W05
Bore diameter: 1½″ (2 × reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (2½″)
BVG 65/40W05 1½″ (2 × reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (2½″) Not Available   VF7x2
BVG 80/50W05
Bore diameter: 2″ (2 × reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (3″)
BVG 80/50W05 2″ (2 × reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (3″) Not Available   VF8x2
BVG 100/65W05
Bore diameter: 2½″ (2 × reduced bore); Max inlet pressure: 500 mbar (7.25 psig); Connection fitting: between two ANSI flanges (4″)
BVG 100/65W05 2½″ (2 × reduced bore) 500 mbar (7.25 psig) between two ANSI flanges (4″) Not Available   VF9x2

BVA models are no longer sold - the BVG replaces all BVA parts. BVG valves are rated for both gas and air.

Description

The butterfly valves BVG, BVH, BVHM and BVHS are designed to adjust volumes of gas, cold and hot air, and flue gas on various appliances and flue gas lines. They are designed for control ratios up to 1:10, and with the mounted actuator IC 20 or IC 40 they are suitable for regulating flow rates for modulating or stage-controlled combustion processes.

Flow rates can be set and fixed using a lever, for example to limit the high-fire rate on the burner. A scale indicates the set angle of opening.

The BVG is a butterfly valve with reduced nominal diameter (reduced by one or two nominal sizes) and can be used to achieve higher control accuracy. This will mean that complex reducing fittings will no longer be required.

Accessories

Model and Description Price Cart
BVG ACC 01
Adapter set BVG with square shaft /B
Contact Us Not Available
BVG ACC 02
Adapter set BVG with free shaft end /B
Contact Us Not Available
BVG ACC 03
Adapter set BVG with manual adjustment /B
Contact Us Not Available
IC-20/40 ACC 01
Fastening set IC-BVG/BVA/BVH/LFC /B
Contact Us Not Available
 
 

Combustion 911

600 Mogadore Rd. Kent, OH 44240

Phone 330-678-3683

Email: support_ab@combustion911.com

View Terms and Conditions

Privacy Policy

©2024 Olstrad Corporation All Rights Reserved

Visit Combustion 911 on LinkedInVisit Combustion 911 on FacebookVisit Combustion 911 on TwitterWatch Combustion 911 videos on YouTubeEmail Combustion 911Read Articles on the Combustion 911 Blog
Olstrad Corporation
ESA Industrial Burners IHEA Member Elektrogas Valves and Regulators

Need a quote? Have a Question?