High Velocity Industrial Burner for Gas BIC

  • Diverse possible applications thanks to wide capacity range of up to 450 kW
  • Suitable for intermittent operation thanks to high outlet velocity and high pulse magnitude
  • High availability due to quick cooling time
  • Ignition and flame control via the burner itself
  • Suitable for any furnace wall thickness thanks to modular length adjustment
  • Maintenance friendly thanks to modular design
  • Low polluting level thanks to optimized combustion
  • For use as ceiling or side-wall burner thanks to arbitrary installation position
  • Use in conjunction with the ceramic tube set TSC in furnaces with brick lining or ceramic fiber lining
  • Installation facilitated by lightweight construction of the BICA
Industrial Burner for Gas BIC

Learn More:
Description   Documentation   Ordering Information   Accessories

Ordering Information

   

Alternate Product

Model and
Description
Model Burner Size Flame Shape Gas Type Length of Burner Extension Position of Burner Head Burner Head ID Construction Stage Lead Time   Model Lead Time Order
BIC 50HB-0/35-(22)C
Burner Size: 50; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 0; Position of Burner Head: 35; Burner Head ID: 22; Construction stage: C
BIC 50HB-0/35-(22)C 50 Long Natural Gas 0 35 22 C 12-14 weeks   EMB-SIK In Stock Learn More
BIC 50RB-0/35-(27)B
Burner Size: 50; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 0; Position of Burner Head: 35; Burner Head ID: 27; Construction stage: B
BIC 50RB-0/35-(27)B 50 Short Natural Gas 0 35 27 B 12-14 weeks   EMB-SIK In Stock Learn More
BIC 50HB-100/135-(22)C
Burner Size: 50; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 100; Position of Burner Head: 135; Burner Head ID: 22; Construction stage: C
BIC 50HB-100/135-(22)C 50 Long Natural Gas 100 135 22 C 12-14 weeks   EMB-SIK In Stock Learn More
BIC 50RB-100/135-(27)B
Burner Size: 50; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 100; Position of Burner Head: 135; Burner Head ID: 27; Construction stage: B
BIC 50RB-100/135-(27)B 50 Short Natural Gas 100 135 27 B 12-14 weeks   EMB-SIK In Stock Learn More
BIC 50HB-200/235-(22)C
Burner Size: 50; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 200; Position of Burner Head: 235; Burner Head ID: 22; Construction stage: C
BIC 50HB-200/235-(22)C 50 Long Natural Gas 200 235 22 C 12-14 weeks   EMB-SIK In Stock Learn More
BIC 50RB-200/235-(27)B
Burner Size: 50; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 200; Position of Burner Head: 235; Burner Head ID: 27; Construction stage: B
BIC 50RB-200/235-(27)B 50 Short Natural Gas 200 235 27 B 12-14 weeks   EMB-SIK In Stock Learn More
BIC 50HB-300/335-(22)C
Burner Size: 50; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 300; Position of Burner Head: 335; Burner Head ID: 22; Construction stage: C
BIC 50HB-300/335-(22)C 50 Long Natural Gas 300 335 22 C 12-14 weeks   EMB-SIK In Stock Learn More
BIC 50RB-300/335-(27)B
Burner Size: 50; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 300; Position of Burner Head: 335; Burner Head ID: 27; Construction stage: B
BIC 50RB-300/335-(27)B 50 Short Natural Gas 300 335 27 B 12-14 weeks   EMB-SIK In Stock Learn More
BIC 50HB-400/435-(22)C
Burner Size: 50; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 400; Position of Burner Head: 435; Burner Head ID: 22; Construction stage: C
BIC 50HB-400/435-(22)C 50 Long Natural Gas 400 435 22 C 12-14 weeks   EMB-SIK In Stock Learn More
BIC 50RB-400/435-(27)B
Burner Size: 50; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 400; Position of Burner Head: 435; Burner Head ID: 27; Construction stage: B
BIC 50RB-400/435-(27)B 50 Short Natural Gas 400 435 27 B 12-14 weeks   EMB-SIK In Stock Learn More
BIC 65RB-0/35-(37)E
Burner Size: 65; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 0; Position of Burner Head: 35; Burner Head ID: 37; Construction stage: E
BIC 65RB-0/35-(37)E 65 Short Natural Gas 0 35 37 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 65HB-0/35-(34)E
Burner Size: 65; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 0; Position of Burner Head: 35; Burner Head ID: 34; Construction stage: E
BIC 65HB-0/35-(34)E 65 Long Natural Gas 0 35 34 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 65RB-100/135-(37)E
Burner Size: 65; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 100; Position of Burner Head: 135; Burner Head ID: 37; Construction stage: E
BIC 65RB-100/135-(37)E 65 Short Natural Gas 100 135 37 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 65HB-100/135-(34)E
Burner Size: 65; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 100; Position of Burner Head: 135; Burner Head ID: 34; Construction stage: E
BIC 65HB-100/135-(34)E 65 Long Natural Gas 100 135 34 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 65RB-200/235-(37)E
Burner Size: 65; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 200; Position of Burner Head: 235; Burner Head ID: 37; Construction stage: E
BIC 65RB-200/235-(37)E 65 Short Natural Gas 200 235 37 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 65HB-200/235-(34)E
Burner Size: 65; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 200; Position of Burner Head: 235; Burner Head ID: 34; Construction stage: E
BIC 65HB-200/235-(34)E 65 Long Natural Gas 200 235 34 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 65RB-300/335-(37)E
Burner Size: 65; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 300; Position of Burner Head: 335; Burner Head ID: 37; Construction stage: E
BIC 65RB-300/335-(37)E 65 Short Natural Gas 300 335 37 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 65HB-300/335-(34)E
Burner Size: 65; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 300; Position of Burner Head: 335; Burner Head ID: 34; Construction stage: E
BIC 65HB-300/335-(34)E 65 Long Natural Gas 300 335 34 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 65RB-400/435-(37)E
Burner Size: 65; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 400; Position of Burner Head: 435; Burner Head ID: 37; Construction stage: E
BIC 65RB-400/435-(37)E 65 Short Natural Gas 400 435 37 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 65HB-400/435-(34)E
Burner Size: 65; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 400; Position of Burner Head: 435; Burner Head ID: 34; Construction stage: E
BIC 65HB-400/435-(34)E 65 Long Natural Gas 400 435 34 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 80HB-0/35-(16)F
Burner Size: 80; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 0; Position of Burner Head: 35; Burner Head ID: 16; Construction stage: F
BIC 80HB-0/35-(16)F 80 Long Natural Gas 0 35 16 F 12-14 weeks   EMB-SIK In Stock Learn More
BIC 80RB-0/35-(6)E
Burner Size: 80; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 0; Position of Burner Head: 35; Burner Head ID: 6; Construction stage: E
BIC 80RB-0/35-(6)E 80 Short Natural Gas 0 35 6 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 80HB-100/135-(16)F
Burner Size: 80; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 100; Position of Burner Head: 135; Burner Head ID: 16; Construction stage: F
BIC 80HB-100/135-(16)F 80 Long Natural Gas 100 135 16 F 12-14 weeks   EMB-SIK In Stock Learn More
BIC 80RB-100/135-(6)E
Burner Size: 80; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 100; Position of Burner Head: 135; Burner Head ID: 6; Construction stage: E
BIC 80RB-100/135-(6)E 80 Short Natural Gas 100 135 6 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 80HB-200/235-(16)F
Burner Size: 80; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 200; Position of Burner Head: 235; Burner Head ID: 16; Construction stage: F
BIC 80HB-200/235-(16)F 80 Long Natural Gas 200 235 16 F 12-14 weeks   EMB-SIK In Stock Learn More
BIC 80RB-200/235-(6)E
Burner Size: 80; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 200; Position of Burner Head: 235; Burner Head ID: 6; Construction stage: E
BIC 80RB-200/235-(6)E 80 Short Natural Gas 200 235 6 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 80HB-300/335-(16)F
Burner Size: 80; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 300; Position of Burner Head: 335; Burner Head ID: 16; Construction stage: F
BIC 80HB-300/335-(16)F 80 Long Natural Gas 300 335 16 F 12-14 weeks   EMB-SIK In Stock Learn More
BIC 80RB-300/335-(6)E
Burner Size: 80; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 300; Position of Burner Head: 335; Burner Head ID: 6; Construction stage: E
BIC 80RB-300/335-(6)E 80 Short Natural Gas 300 335 6 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 80HB-400/435-(16)F
Burner Size: 80; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 400; Position of Burner Head: 435; Burner Head ID: 16; Construction stage: F
BIC 80HB-400/435-(16)F 80 Long Natural Gas 400 435 16 F 12-14 weeks   EMB-SIK In Stock Learn More
BIC 80RB-400/435-(6)E
Burner Size: 80; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 400; Position of Burner Head: 435; Burner Head ID: 6; Construction stage: E
BIC 80RB-400/435-(6)E 80 Short Natural Gas 400 435 6 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 100HB-0/35-(37)E
Burner Size: 100; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 0; Position of Burner Head: 35; Burner Head ID: 37; Construction stage: E
BIC 100HB-0/35-(37)E 100 Long Natural Gas 0 35 37 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 100RB-0/35-(70)E
Burner Size: 100; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 0; Position of Burner Head: 35; Burner Head ID: 70; Construction stage: E
BIC 100RB-0/35-(70)E 100 Short Natural Gas 0 35 70 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 100HB-100/135-(37)E
Burner Size: 100; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 100; Position of Burner Head: 135; Burner Head ID: 37; Construction stage: E
BIC 100HB-100/135-(37)E 100 Long Natural Gas 100 135 37 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 100RB-100/135-(70)E
Burner Size: 100; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 100; Position of Burner Head: 135; Burner Head ID: 70; Construction stage: E
BIC 100RB-100/135-(70)E 100 Short Natural Gas 100 135 70 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 100HB-200/235-(37)E
Burner Size: 100; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 200; Position of Burner Head: 235; Burner Head ID: 37; Construction stage: E
BIC 100HB-200/235-(37)E 100 Long Natural Gas 200 235 37 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 100RB-200/235-(70)E
Burner Size: 100; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 200; Position of Burner Head: 235; Burner Head ID: 70; Construction stage: E
BIC 100RB-200/235-(70)E 100 Short Natural Gas 200 235 70 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 100HB-300/335-(37)E
Burner Size: 100; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 300; Position of Burner Head: 335; Burner Head ID: 37; Construction stage: E
BIC 100HB-300/335-(37)E 100 Long Natural Gas 300 335 37 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 100RB-300/335-(70)E
Burner Size: 100; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 300; Position of Burner Head: 335; Burner Head ID: 70; Construction stage: E
BIC 100RB-300/335-(70)E 100 Short Natural Gas 300 335 70 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 100HB-400/435-(37)E
Burner Size: 100; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 400; Position of Burner Head: 435; Burner Head ID: 37; Construction stage: E
BIC 100HB-400/435-(37)E 100 Long Natural Gas 400 435 37 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 100RB-400/435-(70)E
Burner Size: 100; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 400; Position of Burner Head: 435; Burner Head ID: 70; Construction stage: E
BIC 100RB-400/435-(70)E 100 Short Natural Gas 400 435 70 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 140HB-0/35-(26)E
Burner Size: 140; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 0; Position of Burner Head: 35; Burner Head ID: 26; Construction stage: E
BIC 140HB-0/35-(26)E 140 Long Natural Gas 0 35 26 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 140RB-0/35-(47)E
Burner Size: 140; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 0; Position of Burner Head: 35; Burner Head ID: 47; Construction stage: E
BIC 140RB-0/35-(47)E 140 Short Natural Gas 0 35 47 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 140HB-100/135-(26)E
Burner Size: 140; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 100; Position of Burner Head: 135; Burner Head ID: 26; Construction stage: E
BIC 140HB-100/135-(26)E 140 Long Natural Gas 100 135 26 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 140RB-100/135-(47)E
Burner Size: 140; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 100; Position of Burner Head: 135; Burner Head ID: 47; Construction stage: E
BIC 140RB-100/135-(47)E 140 Short Natural Gas 100 135 47 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 140HB-200/235-(26)E
Burner Size: 140; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 200; Position of Burner Head: 235; Burner Head ID: 26; Construction stage: E
BIC 140HB-200/235-(26)E 140 Long Natural Gas 200 235 26 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 140RB-200/235-(47)E
Burner Size: 140; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 200; Position of Burner Head: 235; Burner Head ID: 47; Construction stage: E
BIC 140RB-200/235-(47)E 140 Short Natural Gas 200 235 47 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 140HB-300/335-(26)E
Burner Size: 140; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 300; Position of Burner Head: 335; Burner Head ID: 26; Construction stage: E
BIC 140HB-300/335-(26)E 140 Long Natural Gas 300 335 26 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 140RB-300/335-(47)E
Burner Size: 140; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 300; Position of Burner Head: 335; Burner Head ID: 47; Construction stage: E
BIC 140RB-300/335-(47)E 140 Short Natural Gas 300 335 47 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 140HB-400/435-(26)E
Burner Size: 140; Flame shape: Long; Gas Type: Natural Gas; Length of Burner Extension: 400; Position of Burner Head: 435; Burner Head ID: 26; Construction stage: E
BIC 140HB-400/435-(26)E 140 Long Natural Gas 400 435 26 E 12-14 weeks   EMB-SIK In Stock Learn More
BIC 140RB-400/435-(47)E
Burner Size: 140; Flame shape: Short; Gas Type: Natural Gas; Length of Burner Extension: 400; Position of Burner Head: 435; Burner Head ID: 47; Construction stage: E
BIC 140RB-400/435-(47)E 140 Short Natural Gas 400 435 47 E 12-14 weeks   EMB-SIK In Stock Learn More

For all other configurations and spare parts Contact Combustion 911

Description

BIC burners are designed for industrial furnaces and firing systems in the iron and steel industries in the precious, non-ferrous, and light metal sector, as well as in the plastics, fiber, and paper industries. Burners BIC and BICA can also be used in thermal incineration installations, as well as in dryers and hot-air generators.

The burner can be used in conjunction with the ceramic tube set TSC in furnaces with brick lining or ceramic fiber lining. No burner quarl is required to serve as combustion chamber.

Thanks to their medium to high outlet velocity (80 to 150 m/s), burners BIC and BICA are ideal for industrial furnaces whose temperature is controlled by an impulse system.

Accessories

Model and Description Price Cart
Ignition Cable
Silicone Rubber Cable High Voltage 7mm (priced per foot).
 
 

Combustion 911

600 Mogadore Rd. Kent, OH 44240

Phone 330-678-3683

Email: support_ab@combustion911.com

View Terms and Conditions

Privacy Policy

©2024 Olstrad Corporation All Rights Reserved

Visit Combustion 911 on LinkedInVisit Combustion 911 on FacebookVisit Combustion 911 on TwitterWatch Combustion 911 videos on YouTubeEmail Combustion 911Read Articles on the Combustion 911 Blog
Olstrad Corporation
ESA Industrial Burners IHEA Member Elektrogas Valves and Regulators

Need a quote? Have a Question?